14.2 MDI-PRC “ALARMS” List
When the Controller communicates with the MDI-PRC, the alarm condition is
represented on the MDI-PRC in a Numeric form is:
Source Device Code and Alarm Code.
The Source Device Code we are interesting in are:
16: This is a local MDI-PRC alarm
02: This is a Traction Controller (AC1) alarm
The Alarm Code List Sourced by the Controller (Source Device Code 02) is the
following:
1: WRONG CONFIG
8: WATCH DOG
13: EEPROM KO
16: AUX OUTPUT KO
17: LOGIC FAILURE #3
18: LOGIC FAILURE #2
19: LOGIC FAILURE #1
30: VMN LOW
31: VMN HIGH
53: STBY I HIGH
55: PROGRAM LIFT LEVER
60: CAPACITOR CHARGE
61: HIGH TEMPERATURE
65: MOTOR TEMPERAT
67: CAN BUS KO
70: ENCODER ERROR
71: HANDBRAKE
73: THERMIC SENS KO
74: DRIVER SHORTED
75: CONTACTOR DRIVER
76: COIL SHORTED
78: VACC NOT OK
79: INCORRECT START
80: FORW+BACK
86: PEDAL WIRE KO
90: LIFT+LOWER
91: LIFT LOW ACTIVE
92: INPUT ERROR #1
94: CURRENT SENS KO
96: ANALOG INPUT
97: OVERLOAD
99: CHECK UP NEEDED
The Alarm Code List Sourced by the MDI-PRC (Source Device Code 16) is the
following:
67: CAN BUS KO The Can Bus communication is broken
70: MDI VALVE2 SHORT At least one of the On/Off Valves Coil is
shorted