3) INVERS. BRAKING
Level 0 to 9. It controls the deceleration ramp when the direction switch is
inverted during travel. At Level 9 the truck brakes abrutly.
4) PEDAL BRAKING
Level 0 to 9. It controls the deceleration ramp when the travel request is
released and the brake pedal switch is pressed to its maximum. At Level 9
the truck brakes abrutly.
5) SPEED LIMIT BRK
Level 0 to 9. It controls the deceleration ramp when the accelerator has
turned down but not completely released. At Level 9 the truck decelerate
abrutly.
6) BRAKE CUTBACK
Level 0 to 9. It controls the deceleration ramp when a speed reduction input
becomes active and the motor slows down. At Level 9 the truck decelerate
abrutly.
7) MAX SPEED FWD
Tipically from 90Hz to 160Hz or something. It determines the maximum
speed in forward direction.
8) MAX SPEED BWD
Tipically from 90Hz to 160Hz or something. It determines the maximum
speed in backward direction.
9) CUTBACK SPEED
Tipically from 10% to 100%. It determines the percentage of the max speed
applied when the cutback switch 1 (SR#1 on CNA#13) is active. When set to
100% the speed reduction is ineffective.
10) CUTBACK SPEED 2
(Standard Version only). Tipically from 10% to 100%. It determines the
percentage of the max speed applied when the cutback switch 2 (SR#2 on
CNA#14) is active. When set to 100% the speed reduction is ineffective.
11) CUTBACK SPEED 3
(Standard Version only). Tipically from 10% to 100%. It determines the
percentage of the max speed applied when the cutback switch 3 (SR#3 on
CNA#15) is active. When set to 100% the speed reduction is ineffective.
12) HS CUTBACK
Tipically from 10% to 100%. It determines the percentage of the max speed
applied when the Hard & Soft function (H&S switch on CNB#4) is active.
When set to 100% the speed reduction is ineffective.
13) FREQUENCY CREEP
Hz value. This is the minimum speed applied when the forward or reverse
switch is closed, but the accelerator at its minimum.
14) MAXIMUM CURRENT
Level 0 to 9. This changes the maximum current of the inverter. At level 9 the
nominal maximum current is supplied; at level 0 the current is almost half of
its nominal value (see 12.4.3.31).