- 15/18/20BT-7, 16/18/20B-7 Pump (05) Test.
Motor Voltage
Voltage supplied to the motor by the controller expressed in % of full battery voltage.
Frequency
Frequency of the voltage and current supplied to the motor.
Encoder
The speed of the motor in Hz. This information comes from the motor Encoders
Slip Value
Difference in speed between the rotating field and the motor shaft (rotator).
Root Mean Square value of the motor current. (RMS Power or the Root Mean Square of
the Power is the average power in an AC circuit. It is like taking the average of the
absolute value of the AC Power).RMS = (1/SQR2).(Peak)
Temperature
Temperature of the aluminum heat sink, holding the MOSFETS. (Controller)
Motor Temperature
Temperature of the motor itself. #1: RH and #2: LH
Accelerator
Voltage comming from accelerator pedal ( LH side = Voltage / RH side = percentage).
Lifting Switch
Status of lifting switch ON / OFF.
1st speed switch
Status of first speed pump switch.
2de speed switch
Status of 2de speed pump switch
3rd speed switch
Status of 3rd speed pump switch.
4th speed switch
Status of 4th speed pump switch.
Hydro speed req
Status of hydro speed request.
Cutback switch
Status of Speed Reduction Microswitch.
The voltage boost supplied to the motor in load conditions expressed in % of full V.
Battery voltage measured at the input to the key switch.